CSA TEW Wire Bare Copper UL1015, UL1028, UL1283, UL1284 105C 600V
CSA TEW Wire Bare Copper UL1015, UL1028, UL1283, UL1284 105C 600V
Sycor Part No | AWG | Stranding | Insulation Thickness (In) | Nom. O.D. (In) | Temp | Voltage Rating | CSA Style | UL Style | Approx Weight LBS./MFT | |
---|---|---|---|---|---|---|---|---|---|---|
A1W2601B | 26 | Solid BC | 0.031 | 0.080 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 2 |
|
A1W2607B | 26 | 7/34 BC | 0.031 | 0.081 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 2 |
|
A1W2401B | 24 | Solid BC | 0.031 | 0.085 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 5 |
|
A1W2407B | 24 | 7/32 BC | 0.031 | 0.086 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 5 |
|
A1W2201B | 26 | Solid BC | 0.031 | 0.093 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 7 |
|
A1W2207B | 22 | 7/30 BC | 0.031 | 0.095 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 7 |
|
A1W2001B | 20 | Solid BC | 0.031 | 0.098 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 7 |
|
A1W2010B | 20 | 10/30 BC | 0.031 | 0.102 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 8 |
|
A1W1801B | 18 | Solid BC | 0.031 | 0.104 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 11 |
|
A1W1816B | 18 | 16/30 BC | 0.031 | 0.112 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 11 |
|
A1W1601B | 16 | Solid BC | 0.031 | 0.115 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 15 |
|
A1W1626B | 16 | 26/30 BC | 0.031 | 0.125 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 15 |
|
A1W1401B | 14 | Solid BC | 0.031 | 0.130 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 22 |
|
A1W1441B | 14 | 41/30 BC | 0.031 | 0.142 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 22 |
|
A1W1201B | 12 | Solid BC | 0.031 | 0.145 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 31 |
|
A1W1265B | 12 | 65/30 BC | 0.031 | 0.155 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 31 |
|
A1W1001B | 10 | Solid BC | 0.031 | 0.166 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 44 |
|
A1W10104B | 10 | 104/30 BC | 0.031 | 0.183 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 44 |
|
A1W08133B | 8 | 133/29 BC | 0.045 | 0.250 | -30°C to 105°C | 600 | CSA TEW | UL1028 | 70 |
|
A1W06133B | 6 | 133/27 BC | 0.060 | 0.335 | -30°C to 105°C | 600 | CSA TEW | UL1283 | 104 |
|
A1W04133B | 4 | 133/25 BC | 0.061 | 0.390 | -30°C to 105°C | 600 | CSA TEW | UL1283 | 170 |
|
A1W02133B | 2 | 133/23 BC | 0.062 | 0.460 | -30°C to 105°C | 600 | CSA TEW | UL1283 | 256 |
|
A1W02665B | 2 | 665/30 BC | 0.063 | 0.470 | -30°C to 105°C | 600 | CSA TEW | UL1283 | 256 |
|
A1W01259B | 1 | 259/25 BC | 0.075 | 0.525 | -30°C to 105°C | 600 | CSA TEW | UL1284 | 323 |
|
A1W01836B | 1 | 836/36 BC | 0.076 | 0.535 | -30°C to 105°C | 600 | CSA TEW | UL1284 | 323 |
|
A1W1/01045B | 1/0 | 1045/30 BC | 0.077 | 0.580 | -30°C to 105°C | 600 | CSA TEW | UL1284 | 400 |
|
A1W2/01330B | 2/0 | 1330/30 BC | 0.078 | 0.640 | -30°C to 105°C | 600 | CSA TEW | UL1284 | 490 |
|
A1W3/01661B | 3/0 | 1330/30 BC | 0.079 | 0.680 | -30°C to 105°C | 600 | CSA TEW | UL1284 | 600 |
|
A1W4/02107B | 4/0 | 2107/30 BC | 0.080 | 0.785 | -30°C to 105°C | 600 | CSA TEW | UL1284 | 750 |
|
TEW Clearance Pricing Available!
TEW Wire Tinned Copper Available. Additional strandings and gauges available upon request. Details are for reference only and are subject to change.
![]() |
|
Description of TEW Wire, UL1015, UL1028, UL1283 & UL1284:
TEW wire consists of a single, soft-drawn copper conductor and thermoplastic PVC insulation. It is a highly versatile wire with a maximum operating voltage of 600V. Some of the TEW wire UL1015 & UL1028 applications include switchboards, appliances, electronic circuits, and machine tool wiring. TEW wire is VW-1 flame test rated and is also resistant to heat, oil, and moisture. Lastly, TEW wire UL1015 & UL1028 come in either tinned or bare copper and are available in various sizes and stranding options.
Approvals of TEW Wire, UL1015, UL1028:
CSA TEW per requirements of Spec C22.2 No 27, FT-1.
UL MTW/AWM per requirements of Spec UL 1063 Subject 758, VW-1.
UL1015, UL1028, UL1283 & UL1284.
Other possible styles: UL1230, 1231, 1232, 1650, 10269.
Construction of TEW Wire, UL1015, UL1028:
Solid or stranded, bare copper conductor(s)
Polyvinyl Chloride (PVC) insulation
(Tinned Copper, Topcoat, Overcoat or Prebond conductors are also available)
Temperature Rating of TEW Wire, UL1015, UL1028:
CSA/UL -30°C to 105°C in dry locations. Not to exceed 60C in wet locations or when exposed to oil or coolant. When TEW Wire UL1015 & UL1028 is used as MTW, applications should not exceed 90C.
Voltage Rating of TEW Wire, UL1015, UL1028:
CSA/UL 600 Volts
Application of TEW Wire, UL1015, UL1028:
TEW Wire UL1015 and UL1028 are typically used for internal wiring of electrical equipment, leads of transformers and motors. TEW wire UL1015 and UL1028 also has an MTW construction, that's used for machine tool wiring. Lastly, TEW wire is used for AWM applications such as the internal wiring of appliances and other equipment.
Colour options for TEW Wire, UL1015, UL1028:
Custom colours, striped and twisted combinations available upon request
Value-Added Services for TEW Wire, UL1015, UL1028:
All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.