CSA SEW-2, UL SF-2 200°C, 600 Volts
CSA SEW-2, UL SF-2 200°C, 600 Volts
Sycor Part No | AWG | Stranding | Insulation Thickness (In) | Nom. O.D. (In) | Temp | Voltage Rating | CSA Style | UL Style | Approx Weight LBS./MFT | |
---|---|---|---|---|---|---|---|---|---|---|
A2Q1807T | 18 | 7/26 | 0.030 | 0.121 | 200°C | 600 | CSA SEW-2 | UL SF-2 | 12 |
|
A2Q1607T | 16 | 7/24 | 0.030 | 0.131 | 200°C | 600 | CSA SEW-2 | UL SF-2 | 16 |
|
A2Q1407T | 14 | 7/22 | 0.030 | 0.147 | 200°C | 600 | CSA SEW-2 | UL SF-2 | 22 |
|
A2Q1219T | 12 | 19/25 | 0.030 | 0.166 | 200°C | 600 | CSA SEW-2 | UL SF-2 | 32 |
|
A2Q1019T | 10 | 19/23 | 0.045 | 0.226 | 200°C | 600 | CSA SEW-2 | UL SF-2 | 62 |
|
A2Q0819T | 8 | 19/21 | 0.060 | 0.314 | 200°C | 600 | CSA SEW-2 | UL SF-2 | 90 |
|
A2Q0619T | 6 | 19/19 | 0.060 | 0.357 | 200°C | 600 | CSA SEW-2 | UL SF-2 | 140 |
|
A2Q0419T | 4 | 19/17 | 0.060 | 0.411 | 200°C | 600 | CSA SEW-2 | UL SF-2 | 205 |
|
A2Q0219T | 2 | 19/15 | 0.060 | 0.470 | 200°C | 600 | CSA SEW-2 | UL SF-2 | 299 |
|
Additional gauges and strandings may be available, contact us to enquire.
|
Description of CSA SEW-2, UL SF-2:
SEW-1 (SF1) and SEW-2 (SF2) wires consist of stranded, tinned or nickel-plated conductors with fibreglass over silicone rubber insulation. The fibreglass braided jackets are coated with a high-temperature finish and are also resistant to moisture and flames. The class 1 and class 2 have maximum operating voltages of 300V and 600V, respectively, and can withstand temperatures of up to 200°C. Silicone and Fibreglass (SRML) motor lead wires are perfect for use in motors, appliances, lighting fixtures, and high-temperature lead wires.
Approvals of CSA SEW-2, UL SF-2:
CSA SEW-2, UL SF-2
Temperature Rating of CSA SEW-2, UL SF-2:
200°C Standard Construction
Construction of CSA SEW-2, UL SF-2:
Solid or stranded tinned copper conductors.
Silicone rubber (SR) insulation with overall non-fraying glass braid with a high-temperature finish
Voltage Rating of CSA SEW-2, UL SF-2:
CSA SEW-2, UL SF-2: 600V
Application of CSA SEW-2, UL SF-2:
The SEW-2 silicone hook-up wire configuration is typically used in the internal wiring of electrical equipment or appliances where moisture, cold and heat may be present.
See Other SEW Constructions:
CSA SEW-1, UL SF-1 300V
CSA SEWF-1, UL SFF-1 (Flexible) 300V,
CSA SEWF-2, UL SFF-2 (Flexible) 600V
Various UL Styles available UL3068, UL3071, UL3075, UL3231, UL3074, UL3122 and others.
Colour options for CSA SEW-2, UL SF-2:
Custom twisted combinations available upon request
Value-Added Services for CSA SEW-2, UL SF-2:
All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.