Toggle Nav
rfq-icon
mobile icon
Close
  • Menu
  • Setting

MV90 XLPE Insulated, PVC Jacketed 25kV Copper Tape Shield

12 Items

per page
Set Descending Direction

MV90 XLPE Insulated, PVC Jacketed 25kV Copper Tape Shield

Download Spec Sheet                                               More info!

    Sycor Part No AWGStrandingConductor Diameter (in)TempVoltage RatingUL Style100% NOM. Diam. Over Insul.100% Jacket Thickness100% Approx Weight Copper100% Approx Weight Alum.133% NOM. Diam. Over Insul.133% Jacket Thickness133% Appr. O.D (in)133% Approx Weight Copper133% Approx Weight Alum.
    MV9025KT100-1 1190.3090°C25kV10720.85807495700.97801.23854675
    MV9025KT100-1/0 1/0190.3490°C25kV10720.89808416161.01801.29974747
    MV9025KT100-2/0 2/0190.3890°C25kV10720.93809536681.05801.331090804
    MV9025KT100-3/0 3/0190.4290°C25kV10720.988010927331.10801.371233872
    MV9025KT100-4/0 4/0190.4890°C25kV10721.038012888341.15801.431408953
    MV9025KT100-250 250 MCM370.5290°C25kV10721.098014449071.21801.4815691031
    MV9025KT100-300 300 MCM370.5790°C25kV10721.148016339891.26801.5317611116
    MV9025KT100-350 350 MCM370.6290°C25kV10721.1880182010671.30801.5819511198
    MV9025KT100-500 500 MCM370.7490°C25kV10721.3080236612921.421101.7626101534
    MV9025KT100-600 600 MCM610.8190°C25kV10721.3980273514451.511101.8830391748
    MV9025KT100-750 750 MCM610.9190°C25kV10721.48110337017581.601101.9735821969
    MV9025KT100-1000 1000 MCM611.0690°C25kV10721.64110430721581.761102.1244832333

    12 Items

    per page
    Set Descending Direction

    Available in 100% and 133% insulation levels. Please contact us to enquire.

    Download Spec Sheet    

    MV90 XLPE Insulated, PVC Jacketed 25kV Copper Tape Shield      

    Description - MV90 25kV Copper Tape Shield:

    Medium voltage shielded power cable.

      

    Approvals - MV90 25kV Copper Tape Shield:

    UL listed as MV-90.
    UL 1072
    ICEA S-93/639/NEMA WC74-STD 5kV-40 Kv SPC
    ICEA S-97-682- SPC
    AEIC CS8 ED - SPC

      

    Construction - MV90 25kV Copper Tape Shield:

    • Soft annealed bare copper conductor, Class B per ASTM B496.
    • Semi conducting cross-linked polyethylene (XLPE) conductor shield.
    • XLPE insulation.
    • Soft annealed uncoated copper tape, 5 mil thick, 25% min overlap metallic shield.
    • Semi conducting cross-linked polyethylene (XLPE) insulation.
    • Oil Resistant, sunlight resistant and flame retardant Polyvinyl Chloride (PVC) compound jacket.

    Temperature Rating - MV90 25kV Copper Tape Shield:

    90°C- Normal Operating Temperature

       

    Voltage Rating - MV90 25kV Copper Tape Shield: 

    25kV 100% and 133%

      

    Application - MV-90 25kV Copper Tape Shield:

    Primary power and distribution circuits in industrial and commercial installations. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.
    Power circuits in generating plants where line to ground fault current are within shield capabilities.
    May be used in wet or dry locations, installed in cable trays, raceways, duct and open air, aerially or directly buried as permitted by NEC.

    ROHS stand compliant

    All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.