    Sycor Part No AWGStrandingTempVoltage RatingUL StyleConductor Diameter (in)100% Insulation Thickness100% Jacket Thickness100% Approx Weight Copper100% Approx Weight Alum.133% Insulation Thickness133% Jacket Thickness133% Appr. O.D (in)133% Approx Weight Copper133% Approx Weight Alum.
    MV905KT100-8 8790°C 5kV10720.130.3560200-0.35600.56200-
    MV905KT100-6 6790°C 5kV10720.170.38602451880.38600.59245188
    MV905KT100-4 4790°C 5kV10720.210.43603112210.43600.64311221
    MV905KT100-2 2790°C 5kV10720.270.48604102670.48600.69410267
    MV905KT100-1 11990°C 5kV10720.300.51604752950.51600.72475295
    MV905KT100-1/0 1/01990°C 5kV10720.340.55605583310.55600.76558331
    MV905KT100-2/0 2/01990°C 5kV10720.380.59606593730.59600.80659373
    MV905KT100-3/0 3/01990°C 5kV10720.420.64808214600.64800.89821460
    MV905KT100-4/0 4/01990°C 5kV10720.480.69809805260.69800.94980526
    MV905KT100-250 2503790°C 5kV10720.520.758011245860.75800.991124586
    MV905KT100-350 3503790°C 5kV10720.620.848014777240.84801.091477786
    MV905KT100-500 5003790°C 5kV10720.740.968019969210.96801.211996921
    MV905KT100-750 7506190°C 5kV10720.911.1480287912661.14801.4128791266
    MV905KT100-1000 1006190°C 5kV10721.061.3080372315731.30801.5737231573

    14 Items

    per page
    Set Descending Direction

    Available in 100% and 133% insulation levels. Please contact us to enquire.

    Download Spec Sheet

      


    Description - MV-90 XLPE Insulated, PVC Jacketed 5 kV Copper Tape Shielded:

    Medium voltage shielded power cable.

      

    Approvals - MV-90 XLPE Insulated, PVC Jacketed 5 kV Copper Tape Shielded:

    UL listed as MV-90                                             
    UL 1072                                               
    Shielded power cables 5,000 to 46,000V     
    5 kV 100% and 133% insulation levels
    ICEA S-97-682: utility                                        
    shielded power cables 5,000 to 46,000V      
    AEIC CS8: extruded dielectric shielded
    Power cables 5,000 to 46,000V

     

    Construction - MV-90 XLPE Insulated, PVC Jacketed 5 kV Copper Tape Shielded:

    • Soft annealed bare copper conductor, Class B per ASTM B496.
    • Semi conducting cross-linked polyethylene (XLPE) conductor shield.
    • XLPE insulation.
    • Semi conducting cross-linked polyethylene (XLPE) insulation.
    • Soft annealed uncoated copper tape, 5 mil thick, 25% min overlap metallic shield.
    • Oil Resistant, sunlight resistant and flame retardant Polyvinyl Chloride (PVC) compound jacket.

    Temperature Rating - MV-90 XLPE Insulated, PVC Jacketed 5 kV Copper Tape Shielded:

    90°C- Normal Operating Temperature

      

    Voltage Rating - MV-90 XLPE Insulated, PVC Jacketed 5 kV Copper Tape Shielded:

    5kV 100% and 133%

      

    Application - MV-90 XLPE Insulated, PVC Jacketed 5 kV Copper Tape Shielded:

    Primary power and distribution circuits in industrial and commercial installations. Power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry locations, installed in cable trays, raceways, duct and open air, aerially or directly buried as permitted by NEC.

    All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.