M16878/29, MIL-W-16878/29 Type F, Silicone Nema HP-6, 600 Volts

13 Items

per page
Set Descending Direction

M16878/29, MIL-W-16878/29 Type F, Silicone Nema HP-6, 600 Volts

Download Spec Sheet                                          More info!

    Sycor Part No AWGStrandingInsulation Thickness (In)TempVoltage RatingMIL Spec Part #
    M16878/29-2407 247/3216/.055150°C600 VoltsM16878/29BEB
    M16878/29-2207 227/3016/.061150°C600 VoltsM16878/29BFB
    M16878/29-2007 207/2816/.069150°C600 VoltsM16878/29BGB
    M16878/29-2010 2010/3016/.069150°C600 VoltsM16878/29BGC
    M16878/29-1807 187/2615/.079150°C600 VoltsM16878/29BHB
    M16878/29-1816 1816/3017/.079150°C600 VoltsM16878/29BHD
    M16878/29-1629 1619/2917/.088150°C600 VoltsM16878/29BJE
    M16878/29-1626 1626/3016/.088150°C600 VoltsM16878/29BJF
    M16878/29-1419 1419/2726/.119150°C600 VoltsM16878/29BKE
    M16878/29-1441 1441/3025/.119150°C600 VoltsM16878/29BKH
    M16878/29-1219 1219/2526/.138150°C600 VoltsM16878/29BLE
    M16878/29-1265 1265/3024/.138150°C600 VoltsM16878/29BLJ
    M16878/29-10105 10105/3019/.161150°C600 VoltsM16878/29BMK

    13 Items

    per page
    Set Descending Direction

    Additional stranding and gauges available upon request.  Please contact us to enquire.

    Download Spec Sheet    

    M16878/29, MIL-W-16878/29 Stranded Wire    

    Description of M16878/29, MIL-W-16878/29:

    MIL-W-16878/29 has a tinned copper conductor with silicone rubber insulation. This construction allows MIL-W-16878/29 to work very well in extreme temperatures and is resistant to flames.

      

    Approvals of M16878/29, MIL-W-16878/29:

    MIL-W-16878/29
    SAE/NEMA HP-6 Type F

      

    Construction of M16878/29, MIL-W-16878/29:

    Tinned plated copper conductor.
    Insulation Silicone rubber

    Temperature Rating of M16878/29, MIL-W-16878/29:

    150°C

        

    Voltage Rating of M16878/29, MIL-W-16878/29:

    600 Volts

       

    Application of M16878/29, MIL-W-16878/29:

    MIL-W-16878/29 has flame retardant silicone for applications close to flames. MIL-W-16878/29 is well known for aerospace, general purpose and medical.

    Colour options available for M16878/29, MIL-W-16878/29:  

    Black Colour 0Brown Colour 1Red Colour 2Orange Colour 3Yellow Colour 4Green Colour 5Blue Colour 6Violet Colour 7Grey Colour 8White Colour 9

      

    Value-Added Services available for M16878/29, MIL-W-16878/29: 

    Resppol VASCut & Strip VASTerminate VAS

    ROHS stand compliant

      

    All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.