Toggle Nav
rfq-icon
Toggle Nav

MGT Wire – UL5107, UL5128 450°C

15 Items

Set Descending Direction

MGT Wire – UL5107, UL5128 450°C

Download Spec Sheet                                              More info!

Share

    Sycor Part No AWGStrandingNom. O.D. (In)TempVoltage RatingCSA StyleUL StyleApprox Weight LBS./MFT
    A1M2207 2270.100450°C600VCSA AWM I A/BUL51078
    A1M2010 20100.104450°C600VCSA AWM I A/BUL51079
    A1M1816 18160.110450°C600VCSA AWM I A/BUL510711
    A1M1626 16260.126450°C600VCSA AWM I A/BUL510715
    A1M1441 14410.139450°C600VCSA AWM I A/BUL510722
    A1M1265 12650.157450°C600VCSA AWM I A/BUL510731
    A1M10105 101050.212450°C600VCSA AWM I A/BUL510779
    A1M08133 81330.262450°C600VCSA AWM I A/BUL510783
    A1M06133 61330.313450°C600VCSA AWM I A/BUL5107113
    A1M04133 41330.368450°C600VCSA AWM I A/BUL5107167
    A1M02133 22590.446450°C600VCSA AWM I A/BUL5107259
    A1M1/0259 1/02590.533450°C600VCSA AWM I A/BUL5107392
    A1M2/0259 2/02590.586450°C600VCSA AWM I A/BUL5107488
    A1M3/0259 3/02590.643450°C600VCSA AWM I A/BUL5107605
    A1M4/0259 4/02590.707450°C600VCSA AWM I A/BUL5107750

    15 Items

    Set Descending Direction

    Download Spec Sheet   

    MGT Wire, UL5107, UL5128

    Description of MGT Wire, UL5107, UL5128:

    Sycor’s MGT high-temperature wire is flexible and has a high resistance to flame, heat and abrasion. MGT is a strong solution for extreme temperature cabling needs because of its consistent strength and high level of flexibility. The MGT wire is constructed with a fiberglass braid and impregnated with Teflon, which adds additional versatility.

    Temperature Rating of MGT Wire, UL5107, UL5128:

    450°C

       

    Construction of MGT Wire, UL5107, UL5128:

    Stranded Nickel Plated Copper Conductor
    Insulation: glass-reinforced mica tapes or mica composite
    Overall Braided Fiberglass Jacket treated with saturant

       

    Voltage Rating of MGT Wire, UL5107, UL5128:

    UL5128: 300 Volts
    UL5107: 600 volts

    Application of MGT Wire, UL5107, UL5128:

    Sycor’s MGT Wire UL5107, UL5128 may be used for applications where consistent extreme temperatures are essential such as iron mills, steel mills, glass plants and cement kilns. The MGT wire also is protected from mechanical damage during handling, installation and servicing.

       

    Approvals of MGT Wire, UL5107, UL5128:

    CSA AWM A/B FT1
    UL5128 / UL5107 VW-1
    NEMA WC 73-2000

    Colour options for MGT Wire:

    Tan Colour 11Natural Colour NAT

       

    Value-Added Services for MGT Wire:

    Resppol VAS

    ROHS stand compliant

       

    All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.