TGGT Wire – UL5127, UL5180, UL5214, UL5256, UL5257 (Teflon Glass Glass Teflon) 250°C
TGGT Wire – UL5127, UL5180, UL5214, UL5256, UL5257 (Teflon Glass Glass Teflon) 250°C
Sycor Part No | AWG | Stranding | Nom. O.D. (In) | Temp | Voltage Rating | CSA Style | Approx Weight LBS./MFT | |
---|---|---|---|---|---|---|---|---|
A6M6V2207 | 22 | 7 | 0.098 | 250°C | 600 | CSA AWM Class 1 Group A/B | 8.03 |
|
A6M6V2007 | 20 | 7 | 0.105 | 250°C | 600 | CSA AWM Class 1 Group A/B | 9.71 |
|
A6M6V1819 | 18 | 19 | 0.112 | 250°C | 600 | CSA AWM Class 1 Group A/B | 11.95 |
|
A6M6V1626 | 16 | 26 | 0.125 | 250°C | 600 | CSA AWM Class 1 Group A/B | 16.10 |
|
A6M6V1441 | 14 | 41 | 0.137 | 250°C | 600 | CSA AWM Class 1 Group A/B | 21.78 |
|
A6M6V1265 | 12 | 65 | 0.155 | 250°C | 600 | CSA AWM Class 1 Group A/B | 30.52 |
|
A6M6V10105 | 10 | 105 | 0.181 | 250°C | 600 | CSA AWM Class 1 Group A/B | 45.84 |
|
A6M6V08133 | 8 | 133 | 0.229 | 250°C | 600 | CSA AWM Class 1 Group A/B | 70.60 |
|
A6M6V06133 | 6 | 133 | 0.294 | 250°C | 600 | CSA AWM Class 1 Group A/B | 114.20 |
|
A6M6V04133 | 4 | 133 | 0.374 | 250°C | 600 | CSA AWM Class 1 Group A/B | 182.20 |
|
A6M6V02133 | 2 | 133 | 0.443 | 250°C | 600 | CSA AWM Class 1 Group A/B | 272.10 |
|
A6M6V1/0259 | 1/0 | 259 | 0.531 | 250°C | 600 | CSA AWM Class 1 Group A/B | 410.95 |
|
A6M6V2/0259 | 2/0 | 259 | 0.582 | 250°C | 600 | CSA AWM Class 1 Group A/B | 506.05 |
|
A6M6V3/0259 | 3/0 | 259 | 0.636 | 250°C | 600 | CSA AWM Class 1 Group A/B | 624.59 |
|
A6M6V4/0259 | 4/0 | 259 | 0.702 | 250°C | 600 | CSA AWM Class 1 Group A/B | 770.66 |
|
Description of TGGT, UL5127, UL5180, UL5214, UL5256, UL5257:
Sycor’s TGGT wire is flexible and has a high resistance to flame, heat and abrasion. TGGT wire is typically used in high-temperature environments inside appliances.
Construction of TGGT Wire:
Stranded Nickel Plated Copper Conductor
PTFE Insulation Tapes wrapped with Fiberglass Yarns
Overall Braided Fiberglass Jacket treated with saturant
Voltage of TGGT Wire:
UL styles vary: 300 volts or 600 Volts
Temperature of TGGT Wire:
250°C
Application of TGGT Wire:
Sycor’s TGGT wire may be used for internal wiring of industrial, commercial or residential ovens, furnaces, cooking or drying equipment.
Approvals of TGGT Wire:
UL styles vary:
UL5180, UL5257, UL5256, UL5214, UL5127
CSA AWM Class 1, Group A/B FT-2
Colour options for TGGT Wire:
*Additional standard colour options may be available for special order, would be subject to MFG MOQs*
Value-Added Services for TGGT Wire:
All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.