Fire Alarm Shielded Multi-Conductor Cable (UL FPL)
Fire Alarm Shielded Multi-Conductor Cable (UL FPL)
Sycor Part No | AWG | # of Conductors | Stranding | Insulation Thickness (In) | Nom. O.D. (In) | Jacket Thickness (In) | Temp | Voltage Rating | CSA Style | Color Code | Approx Weight LBS./MFT | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
SCX156-1802 | 18 | 2 | Solid | 0.015 | 0.211 | 0.030 | -20°C to 105°C | 300 | FT-4 | 7 | 30 |
|
SCX156-1803 | 18 | 3 | Solid | 0.015 | 0.226 | 0.030 | -20°C to 105°C | 300 | FT-4 | 7 | 39 |
|
SCX156-1804 | 18 | 4 | Solid | 0.015 | 0.240 | 0.030 | -20°C to 105°C | 300 | FT-4 | 7 | 46 |
|
SCX156-1805 | 18 | 5 | Solid | 0.015 | 0.255 | 0.030 | -20°C to 105°C | 300 | FT-4 | 7 | 55 |
|
SCX156-1602 | 16 | 2 | Solid | 0.015 | 0.232 | 0.030 | -20°C to 105°C | 300 | FT-4 | 7 | 38 |
|
SCX156-1603 | 16 | 3 | Solid | 0.015 | 0.247 | 0.030 | -20°C to 105°C | 300 | FT-4 | 7 | 60 |
|
SCX156-1604 | 16 | 4 | Solid | 0.015 | 0.265 | 0.030 | -20°C to 105°C | 300 | FT-4 | 7 | 76 |
|
SCX156-1605 | 16 | 5 | Solid | 0.015 | 0.282 | 0.030 | -20°C to 105°C | 300 | FT-4 | 7 | 91 |
|
SCX156-1402 | 14 | 2 | Solid | 0.015 | 0.262 | 0.032 | -20°C to 105°C | 300 | FT-4 | 7 | 52 |
|
SCX156-1404 | 14 | 4 | Solid | 0.015 | 0.302 | 0.032 | -20°C to 105°C | 300 | FT-4 | 7 | 84 |
|
SCX156-1202 | 12 | 2 | Solid | 0.020 | 0.316 | 0.032 | -20°C to 105°C | 300 | FT-4 | 7 | 74 |
|
Description of Shielded Fire Alarm Cable, UL FPL:
Sycor’s shielded fire alarm cable is a designated fire cable that’s typically used because of its approved safety measures. The shielded fire alarm cable also has low-smoke PVC and is used for essential detection or other forms of important monitoring applications.
Construction of Shielded Fire Alarm Cable, UL FPL:
Twisted solid, bare copper conductor fully annealed
100% foil shield with tinned copper drain wire
Red (PVC) polyvinyl chloride insulation
Premium grade, colour-coded polyvinylchloride (PVC) jacket
Voltage Rating of Shielded Fire Alarm Cable, UL FPL:
300 Volts
Temperature Rating of Shielded Fire Alarm Cable, UL FPL:
-20°C to +105°C
Application of Shielded Fire Alarm Cable, UL FPL:
Sycor’s shielded fire alarm cable meets California state requirements for fire prevention, making this specific shielded fire alarm cable perfect for applications involving wiring fire alarms, smoke detectors, burglar alarms, fire protective circuits, vocal communication devices, and power-limited circuits.
Approvals of Shielded Fire Alarm Cable, UL FPL:
NEC Article 760
UL FPL (UL: 60°C, 300V)
California State Fire Marshall Approved
Passes UL 70,000 BTU Vertical Tray Flame Test
CSA FT-4
Colour options for Shielded Fire Alarm Cable, UL FPL:
Colour Chart 7 | ||
NO. Of Cond. | Colour | Mark Colour |
1 | Black | - |
2 | red | - |
3 | Green | - |
4 | Blue | - |
5 | Brown | - |
6 | Orange | - |
7 | Black | White |
8 | Red | White |
9 | Green | White |
10 | Yellow | White |
11 | Red | Black |
12 | Green | Black |
13 | Yellow | Black |
14 | Green | Red |
15 | Yellow | Red |
16 | White | Brown |
17 | Green | Brown |
18 | Yellow | Brown |
19 | White | Orange |
20 | Black | Orange |
21 | Red | Orange |
22 | Green | Orange |
23 | Brown | Orange |
24 | White | Blue |
25 | Red | Blue |
26 | Yellow | Blue |
27 | Brown | Blue |
28 | Black | Red |
29 | White | Red |
30 | Broan | Red |
Value-Added Services for Fire alarm Shielded Cable, UL FPL:
All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.