CSA TEW Wire Tinned Copper UL1015, UL1028, UL1283, UL1284 105°C 600V
CSA TEW Wire Tinned Copper UL1015, UL1028, UL1283, UL1284 105°C 600V
Sycor Part No | AWG | Stranding | Insulation Thickness (In) | Nom. O.D. (In) | Temp | Voltage Rating | CSA Style | UL Style | Approx Weight LBS./MFT | |
---|---|---|---|---|---|---|---|---|---|---|
A1U2601T | 26 | Solid TC | 0.031 | 0.080 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 2 |
|
A1U2607T | 26 | 7/34 TC | 0.031 | 0.081 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 2 |
|
A1U2401T | 24 | Solid TC | 0.031 | 0.085 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 5 |
|
A1U2407T | 24 | 7/32 TC | 0.031 | 0.086 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 5 |
|
A1U2201T | 22 | Solid TC | 0.031 | 0.093 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 7 |
|
A1U2207T | 22 | 7/30 TC | 0.031 | 0.095 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 7 |
|
A1U2001T | 20 | Solid TC | 0.031 | 0.098 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 7 |
|
A1U2010T | 20 | 10/30 TC | 0.031 | 0.102 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 8 |
|
A1U1801T | 18 | Solid TC | 0.031 | 0.104 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 11 |
|
A1U1816T | 18 | 16/30 TC | 0.031 | 0.112 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 11 |
|
A1U1601T | 16 | Solid TC | 0.031 | 0.115 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 15 |
|
A1U1626T | 16 | 26/30 TC | 0.031 | 0.125 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 15 |
|
A1U1401T | 14 | Solid TC | 0.031 | 0.130 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 22 |
|
A1U1441T | 14 | 41/30 TC | 0.031 | 0.142 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 22 |
|
A1U1201T | 12 | Solid TC | 0.031 | 0.145 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 31 |
|
A1U1265T | 12 | 65/30 TC | 0.031 | 0.155 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 31 |
|
A1U1001T | 10 | Solid TC | 0.031 | 0.166 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 44 |
|
A1U10104T | 10 | 104/30 TC | 0.031 | 0.183 | -30°C to 105°C | 600 | CSA TEW | UL1015 | 44 |
|
A1U08133T | 8 | 133/29 TC | 0.045 | 0.250 | -30°C to 105°C | 600 | CSA TEW | UL1028 | 70 |
|
A1U06133T | 6 | 133/27 BC | 0.060 | 0.335 | -30°C to 105°C | 600 | CSA TEW | UL1283 | 104 |
|
A1U04133T | 4 | 133/25 TC | 0.061 | 0.390 | -30°C to 105°C | 600 | CSA TEW | UL1283 | 170 |
|
A1U02133T | 2 | 133/23 TC | 0.062 | 0.460 | -30°C to 105°C | 600 | CSA TEW | UL1283 | 256 |
|
A1U02665T | 2 | 665/30 TC | 0.063 | 0.470 | -30°C to 105°C | 600 | CSA TEW | UL1283 | 256 |
|
A1U01259T | 1 | 259/25 TC | 0.075 | 0.525 | -30°C to 105°C | 600 | CSA TEW | UL1284 | 323 |
|
A1U01836T | 1 | 836/36 TC | 0.076 | 0.535 | -30°C to 105°C | 600 | CSA TEW | UL1284 | 323 |
|
A1U1/01045T | 1/0 | 1045/30 TC | 0.077 | 0.580 | -30°C to 105°C | 600 | CSA TEW | UL1284 | 400 |
|
A1U2/01330T | 2/0 | 1330/30 TC | 0.078 | 0.640 | -30°C to 105°C | 600 | CSA TEW | UL1284 | 490 |
|
A1U3/01661T | 3/0 | 1330/30 TC | 0.079 | 0.680 | -30°C to 105°C | 600 | CSA TEW | UL1284 | 600 |
|
A1U4/02107T | 4/0 | 2107/30 TC | 0.080 | 0.785 | -30°C to 105°C | 600 | CSA TEW | UL1284 | 750 |
|
TEW Wire Bare Copper Available. Additional strandings and gauges available upon request. Details are for reference only and are subject to change.
Description of CSA TEW Wire, UL1015, UL1028:
TEW wire UL1015 & UL1028 consists of a single, soft-drawn copper conductor and thermoplastic PVC insulation. It is a highly versatile wire with a maximum operating voltage of 600V. Some of TEW wires applications include switchboards, appliances, electronic circuits, and machine tool wiring. CSA TEW wire UL1015 & UL1028 is VW-1 flame test rated and is also resistant to heat, oil, and moisture. Lastly, CSA TEW wire UL1015 & UL1028 comes in either tinned or bare copper and is available in various sizes and stranding options.
Approvals of CSA TEW Wire, UL1015, UL1028:
CSA TEW per requirements of Spec C22.2 No 27, FT-1.
UL MTW/AWM per requirements of Spec UL 1063 Subject 758, VW-1.
UL1015, UL1028, UL1283, UL1284.
Other possible styles: UL1230, 1231, 1232, 1650, 10269.
Construction of CSA TEW Wire, UL1015, UL1028:
Solid or stranded, tinned copper conductor(s)
Polyvinyl Chloride (PVC) insulation
(Bare Copper, Topcoat, Overcoat or Prebond conductors are also available)
Voltage for CSA TEW Wire, UL1015, UL1028:
CSA/UL 600 Volts
Bend Radius
Flexible 10x Outer-Ø
Fixed 5x Outer- Ø
Temperature for CSA TEW Wire, UL1015, UL1028:
CSA/UL -30°C to 105°C in dry locations. Not to exceed 60°C in wet locations or when exposed to oil or coolant. When CSA TEW wire is used as MTW, applications should not exceed 90°C
Application of CSA TEW Wire, UL1015, UL1028:
TEW Wire UL1015 & UL1028 are typically used for internal wiring of electrical equipment, leads of transformers and motors. This type of lead wire also has an MTW construction, that's used for machine tool wiring. Lastly, CSA TEW Wire UL1015 & UL1028 can be used for AWM applications such as the internal wiring of appliances and other equipment.
Colour options for CSA TEW Wire:
Custom colours, striped and twisted combinations available upon request
Value-Added Services for CSA TEW Wire:
All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.