Braided Silicone High-Temp. Lead Wire UL3252, UL3254 (250°C)
Braided Silicone High-Temp. Lead Wire UL3252, UL3254 (250°C)
Sycor Part No | AWG | Stranding | Nom. O.D. (In) | Temp | Voltage Rating | CSA Style | UL Style | Approx Weight LBS./MFT | |
---|---|---|---|---|---|---|---|---|---|
A3M3V2207 | 22 | 7 | 0.106 | 250°C | 300V | CSA AWM Class I A/B | UL3254 | 7.42 |
|
A3M3V2007 | 20 | 7 | 0.112 | 250°C | 300V | CSA AWM Class I A/B | UL3254 | 8.79 |
|
A3M3V1819 | 18 | 19 | 0.118 | 250°C | 300V | CSA AWM Class I A/B | UL3254 | 11.1 |
|
A3M3V1626 | 16 | 26 | 0.134 | 250°C | 300V | CSA AWM Class I A/B | UL3254 | 15.41 |
|
A3M3V1441 | 14 | 41 | 0.149 | 250°C | 300V | CSA AWM Class I A/B | UL3254 | 20.95 |
|
A3M3V1265 | 12 | 65 | 0.168 | 250°C | 300V | CSA AWM Class I A/B | UL3254 | 30.14 |
|
A3M6V2207 | 22 | 7 | 0.106 | 250°C | 600V | CSA AWM Class I A/B | UL3252 | 7.42 |
|
A3M6V2010 | 20 | 10 | 0.112 | 250°C | 600V | CSA AWM Class I A/B | UL3252 | 8.79 |
|
A3M6V1819 | 18 | 19 | 0.116 | 250°C | 600V | CSA AWM Class I A/B | UL3252 | 11.1 |
|
A3M6V1626 | 16 | 26 | 0.128 | 250°C | 600V | CSA AWM Class I A/B | UL3252 | 15.41 |
|
A3M6V1441 | 14 | 41 | 0.144 | 250°C | 600V | CSA AWM Class I A/B | UL3252 | 20.95 |
|
A3M6V1265 | 12 | 65 | 0.166 | 250°C | 600V | CSA AWM Class I A/B | UL3252 | 30.14 |
|
A3M6V10105 | 10 | 105 | 0.187 | 250°C | 600V | CSA AWM Class I A/B | UL3252 | 43.97 |
|
Description of UL3252, UL3254:
Sycor’s UL3252 and UL3254 braided fiberglass over silicone insulation is a high-temperature wire known for its extreme resistance to heat and flame, abrasion, chemicals, moisture, UV, ozone, and extreme cold. The use of silicone in place of teflon® makes this high-temperature wire much lighter and easier to use.
Temperature Rating of UL3252, UL3254:
250°C
Construction of UL3252, UL3254:
Stranded Nickel Plated Copper Conductor
(Bare or Tinned Copper Conductor Available)
Extruded Silicone Rubber Insulation
Braided Fiberglass with high temperature finish outer covering
Voltage Rating of UL3252, UL3254:
UL3254: 300 Volts
UL3252: 600 Volts
Application of UL3252, UL3254:
Sycor’s UL3252 and UL3254 high-temperature wire as the name suggests excels as motor lead wire in hazardous conditions. This highly resistant cable is effective in domestic, commercial and industrial heating applications and as a lead wire for electrical equipment where environmental exposure to both high and low temperature is a concern.
Approvals of UL3252, UL3254:
UL3252, UL3254 VW-1
CSA AWM Class I A/B FT-2
Colour options for UL3252, UL3254:
Value-Added Services for UL3252, UL3254:
All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.