XLP-CPE Tray Cable with Ground, UL1277
XLP-CPE Tray Cable with Ground, UL1277
Sycor Part No | AWG | # of Conductors | Ground Cond. Size | Stranding | Nom. O.D. (In) | Jacket Thickness (Mils) | Temp | Voltage Rating | UL Style | Approx Weight LBS./MFT | |
---|---|---|---|---|---|---|---|---|---|---|---|
SCXTCXCG0803 | 8 | 3 | 10 | 7 / .0486 | 0.636 | 60 | 90°C | 600 Volts | UL1277 | 318 |
|
SCXTCXCG0804 | 8 | 4 | 10 | 7 / .0486 | 0.695 | 60 | 90°C | 600 Volts | UL1277 | 388 |
|
SCXTCXCG0603 | 6 | 3 | 8 | 7 / .0612 | 0.710 | 60 | 90°C | 600 Volts | UL1277 | 454 |
|
SCXTCXCG0604 | 6 | 4 | 8 | 7 / .0612 | 0.780 | 60 | 90°C | 600 Volts | UL1277 | 563 |
|
SCXTCXCG0403 | 4 | 3 | 8 | 7 / .0772 | 0.810 | 60 | 90°C | 600 Volts | UL1277 | 660 |
|
SCXTCXCG0404 | 4 | 4 | 8 | 7 / .0772 | 0.935 | 80 | 90°C | 600 Volts | UL1277 | 826 |
|
SCXTCXCG0203 | 2 | 3 | 6 | 7 / .0974 | 0.975 | 80 | 90°C | 600 Volts | UL1277 | 966 |
|
SCXTCXCG0204 | 2 | 4 | 6 | 7 / .0974 | 1.070 | 80 | 90°C | 600 Volts | UL1277 | 1210 |
|
SCXTCXCG0103 | 1 | 3 | 6 | 19 / .0664 | 1.120 | 80 | 90°C | 600 Volts | UL1277 | 1155 |
|
SCXTCXCG0104 | 1 | 4 | 6 | 19 / .0664 | 1.235 | 80 | 90°C | 600 Volts | UL1277 | 1577 |
|
SCXTCXCG1/003 | 1/0 | 3 | 6 | 19 / .0745 | 1.205 | 80 | 90°C | 600 Volts | UL1277 | 1503 |
|
SCXTCXCG1/004 | 1/0 | 4 | 6 | 19 / .0745 | 1.230 | 80 | 90°C | 600 Volts | UL1277 | 1912 |
|
SCXTCXCG2/003 | 2/0 | 3 | 6 | 19 / .0837 | 1.295 | 80 | 90°C | 600 Volts | UL1277 | 1811 |
|
SCXTCXCG2/004 | 2/0 | 4 | 6 | 19 / .0837 | 1.435 | 80 | 90°C | 600 Volts | UL1277 | 2402 |
|
SCXTCXCG3/003 | 3/0 | 3 | 4 | 19 / .0940 | 1.415 | 80 | 90°C | 600 Volts | UL1277 | 2240 |
|
SCXTCXCG3/004 | 3/0 | 4 | 4 | 19 / .0940 | 1.565 | 80 | 90°C | 600 Volts | UL1277 | 2879 |
|
SCXTCXCG4/003 | 4/0 | 3 | 4 | 19 / .1055 | 1.530 | 80 | 90°C | 600 Volts | UL1277 | 2705 |
|
SCXTCXCG4/004 | 4/0 | 4 | 4 | 19 / .1055 | 1.755 | 110 | 90°C | 600 Volts | UL1277 | 3573 |
|
SCXTCXCG25003 | 250 MCM | 3 | 4 | 37 / .0822 | 1.730 | 110 | 90°C | 600 Volts | UL1277 | 3273 |
|
SCXTCXCG25004 | 250 MCM | 4 | 4 | 37 / .0822 | 1.910 | 110 | 90°C | 600 Volts | UL1277 | 4206 |
|
SCXTCXCG35003 | 350 MCM | 3 | 3 | 36 / .0973 | 1.955 | 110 | 90°C | 600 Volts | UL1277 | 4389 |
|
SCXTCXCG35004 | 350 MCM | 4 | 3 | 36 / .0973 | 2.160 | 110 | 90°C | 600 Volts | UL1277 | 5809 |
|
SCXTCXCG50003 | 500 MCM | 3 | 2 | 36 / .1162 | 2.210 | 110 | 90°C | 600 Volts | UL1277 | 6094 |
|
SCXTCXCG50004 | 500 MCM | 4 | 2 | 36 / .1162 | 2.450 | 110 | 90°C | 600 Volts | UL1277 | 7794 |
|
Additional strandings and gauges available upon request. Please contact us to enquire.
Description of XLP-CPE Tray Cable, UL1277:
XLP-CPE tray cable UL1277 is a designated power and control cable that has the ability to be used in rough environments. XLP-CPE tray cable is approved for class I and II, division 2 hazardous locations and air, in ducts, conduits or direct burial.
Approvals of XLP-CPE Tray Cable, UL1277:
UL1277
IEEE 1202
ICEA 210,000 BTU flame tests
ICEA S-73-532, NEMA WC70
Construction of XLP-CPE Tray Cable, UL1277:
Stranded bare copper conductor
Crosslinked polyethylene (XLP) insulation
Chlorinated Polyethylene (CPE) Jacket
Temperature Rating of XLP-CPE Tray Cable, UL1277:
90°C
Voltage Rating of XLP-CPE Tray Cable, UL1277:
600 Volts
Application of XLP-CPE Tray Cable, UL1277:
XLP-CPE tray cable is built with excellent resistance and typically used in an application involving power and signal control. XLP-CPE tray cable
Alternative Product
Colour options for XLP-CPE Tray Cable:
Value-Added Services for XLP-CPE Tray Cable:
All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.