DLO 2kv Wind Turbine Power Cable
DLO 2kv Wind Turbine Power Cable
Sycor Part No | AWG | Stranding | Insulation Thickness (In) | Nom. O.D. (In) | Jacket Thickness (In) | Temp | Voltage Rating | CSA Style | UL Style | Approx Weight LBS./MFT | Ampacity | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
DLO1/0273B | 1/0 | 273/24 | 0.080 | 0.69 | 0.045 | -40°C to 90°C | 2kv | CSA RW90 | UL RHH-RHW-2 | 515 | 170 & 260 |
|
DLO2/0324B | 2/0 | 324/24 | 0.080 | 0.73 | 0.045 | -40°C to 90°C | 2kv | CSA RW90 | UL RHH-RHW-2 | 580 | 195 & 300 |
|
DLO3/0448B | 3/0 | 448/24 | 0.080 | 0.81 | 0.045 | -40°C to 90°C | 2kv | CSA RW90 | UL RHH-RHW-2 | 770 | 225 & 350 |
|
DLO4/0523B | 4/0 | 532/24 | 0.080 | 0.94 | 0.065 | -40°C to 90°C | 2kv | CSA RW90 | UL RHH-RHW-2 | 930 | 260 & 405 |
|
DLO262646B | 262.6 | 646/24 | 0.090 | 0.98 | 0.065 | -40°C to 90°C | 2kv | CSA RW90 | UL RHH-RHW-2 | 1130 | 296 & 467 |
|
DLO313775B | 313.3 | 775/24 | 0.090 | 1.06 | 0.065 | -40°C to 90°C | 2kv | CSA RW90 | UL RHH-RHW-2 | 1295 | 326 & 522 |
|
DLO373925B | 373.7 | 925/24 | 0.090 | 1.10 | 0.065 | -40°C to 90°C | 2kv | CSA RW90 | UL RHH-RHW-2 | 1545 | 362 & 591 |
|
DLO4441110B | 444.4 | 1110/24 | 0.090 | 1.17 | 0.065 | -40°C to 90°C | 2kv | CSA RW90 | UL RHH-RHW-2 | 1820 | 400 & 652 |
|
DLO5001221B | 500 | 1221/24 | 0.090 | 1.20 | 0.065 | -40°C to 90°C | 2kv | CSA RW90 | UL RHH-RHW-2 | 2100 | 430 & 700 |
|
DLO5351332B | 535.3 | 1332/24 | 0.090 | 1.21 | 0.065 | -40°C to 90°C | 2kv | CSA RW90 | UL RHH-RHW-2 | 2195 | 445 & 728 |
|
DLO6461591B | 646.4 | 1591/24 | 0.090 | 1.28 | 0.065 | -40°C to 90°C | 2kv | CSA RW90 | UL RHH-RHW-2 | 2560 | 493 & 815 |
|
DLO7771924B | 777.7 | 1924/24 | 0.090 | 1.37 | 0.065 | -40°C to 90°C | 2kv | CSA RW90 | UL RHH-RHW-2 | 3050 | 545 & 904 |
|
Additional strandings and gauges available upon request.
Description of DLO Wind Power Cable:
Sycor’s 2kv Wind Turbine DLO cables are useful in dry or wet outdoor locations because of its resistance to oils, heat, flame, abrasion, alkalies and acids. The 2kv Wind Turbine DLO cable is also a designated portable power cable that can either be handled more often because of its flexible properties or last for very long periods of time without requiring maintenance.
Construction of DLO Wind Power Cable:
Stranded bare annealed copper
Paper or polyester tape separator
EPDM rubber insulation
Black, heavy-duty CPE sunlight resistant jacket extruded
Voltage Rating of DLO Wind Power Cable:
2000 Volts
Temperature Rating of DLO Wind Power Cable:
-40°C to 90°C
Application of DLO Wind Power Cable:
Sycor’s 2kv Wind Turbine DLO cable is designed to transfer power from wind turbines to an appropriate power source. The 2kv Wind Turbine DLO cable is a good choice for applications involving drilling rips, motor leads, in shipyards, conduit ducts, railroad and transit car wiring and even electrical earth moving equipment.
Approvals of DLO Wind Power Cable:
MSHA accepted
UL Type RHH-RHW-2 per UL 44
CSA Type RW90 1kV per C22.2 No. 38-95
Meets FT-4 and VW-1 Flame Tests
IEEE 1202