Toggle Nav
rfq-icon
Toggle Nav

Shielded and Jacketed Flat Ribbon Cable

8 Items

Set Descending Direction

Shielded and Jacketed Flat Ribbon Cable

Download Spec Sheet                                                 More info!

Share

    Sycor Part No AWG# of ConductorsStrandingJacket Thickness (In)TempVoltage RatingUL Style
    P2J2814T 28147/360.035105°C150 VoltsUL2912
    P2J2815T 28157/360.035105°C150 VoltsUL2912
    P2J2816T 28167/360.035105°C150 VoltsUL2912
    P2J2820T 28207/360.035105°C150 VoltsUL2912
    P2J2825T 28257/360.035105°C150 VoltsUL2912
    P2J2826T 28267/360.035105°C150 VoltsUL2912
    P2J2834T 28347/360.035105°C150 VoltsUL2912
    P2J2826T 28267/360.035105°C150 VoltsUL2912

    8 Items

    Set Descending Direction

    Additional conductor counts available upon request.
    Available with standard grey or rainbow twisted pair ribbon cable.
    Available without shield or with other shield configurations. Grey Jacket may also be available.

    Download Spec Sheet   

    Width = # of Cond.  x  0.050
    Span = # of Cond.  x  0.050  -  0.050

    Shielded and Jacketed Flat Ribbon Cable

    Description of Jacketed Ribbon Cable:

    The shielded and jacketed ribbon cable is used in environments where EMI/RFI and other interference is a concern. The .050” pitch allows for mass termination by widely used and low-cost IDC connectors. 

      

    Approvals of Jacketed Ribbon Cable:

    CSA AWM (available)
    UL Style varies

      

    Construction of Jacketed Ribbon Cable:

    Stranded tinned copper conductors, centres spaced at .050” (1.27 mm) intervals               
    Extruded Grey Polyvinyl Chloride (PVC) insulation
    Aluminum/Mylar Tape Shield and ground wire
    Black PVC Jacket
    Shield Construction Drain / Tape Shield: AL/PET
    Conductor Resistance ohms/1000 ft (ohms/Km): 67.5 (221.4)
    • Capacitance Ground-Signal (G-S) pF/ft (pF/m): 20 (58)
    Impedance (G-S-G): 70 ohms

    Temperature Rating ­of Jacketed Ribbon Cable:

    CSA & UL 105°C

      

    Voltage Rating ­of Jacketed Ribbon Cable:

    CSA & UL 150 Volts

      

    Application ­of Jacketed Ribbon Cable:

    The shielded and jacketed ribbon cable is typically used for the internal wiring of electronic equipment where EMI/RFI Shielding is required.

    Colour options for Jacketed Ribbon Cable:

    Black Colour 0

      

    Value-Added Services for Jacketed Ribbon Cable:

    Resppol VASCut & Strip VASTerminate VAS

    ROHS stand compliant

      

    All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.