Toggle Nav
rfq-icon
Toggle Nav

MV105 25kV Copper Tape Shield, EPR Insulated, PVC Jacketed

13 Items

Set Descending Direction

MV105 25kV Copper Tape Shield, EPR Insulated, PVC Jacketed

Download Spec Sheet                                                   More info!

Share

    Sycor Part No AWGStrandingConductor Diameter (in)TempVoltage RatingUL Style100% NOM. Diam. Over Insul.100% Jacket Thickness100% Approx Weight Copper100% Approx Weight Alum.133% NOM. Diam. Over Insul.133% Jacket Thickness133% Appr. O.D (in)133% Approx Weight Copper133% Approx Weight Alum.
    MV10525KT100-1 1190.30105°C25kV10720.86808296490.97801.23910713
    MV10525KT100-1/0 1/0190.34105°C25kV10720.90809266991.02801.301086859
    MV10525KT100-2/0 2/0190.38105°C25kV10720.948010437571.06801.341208922
    MV10525KT100-3/0 3/0190.42105°C25kV10720.998011878271.11801.391358997
    MV10525KT100-4/0 4/0190.48105°C25kV10721.048013909351.16801.4415411086
    MV10525KT100-250 250 MCM370.52105°C25kV10721.1080155310161.22801.5017091172
    MV10525KT100-300 300 MCM370.57105°C25kV10721.1580174811031.27801.5519091264
    MV10525KT100-350 350 MCM370.62105°C25kV10721.1980194011871.31801.5921061353
    MV10525KT100-400 400 MCM370.66105°C25kV10721.2480212912691.36801.6423001440
    MV10525KT100-500 500 MCM370.74105°C25kV10721.3180250114261.431101.7827861710
    MV10525KT100-600 600 MCM610.81105°C25kV10721.4080288115901.521101.9032291939
    MV10525KT100-750 750 MCM610.91105°C25kV10721.49110353119181.621101.9937872174
    MV10525KT100-1000 1000 MCM611.06105°C25kV10721.65110448823381.771102.1447112561

    13 Items

    Set Descending Direction

    Available in 100% and 133% insulation levels.  Please contact us to enquire.

    Download Spec Sheet   

    MV105 EPR Insulated, PVC Jacketed 25kV Copper Tape Shield   

    Description - MV105 25kV Copper Tape Shield:

    The MV105 25kV Copper Tape Shield is a designated medium voltage shielded power cable.

    Approvals - MV105 25kV Copper Tape Shield:

    ICEA S-93-639/NEMA WC 74
    ICEA S-97-682
    AEIC CS8
    UL listed as MV-105.
    UL 1072

      

    Construction - MV105 25kV Copper Tape Shield:

    • Soft annealed bare copper conductor, Class B per ASTM B496.
    • Semi-conducting cross-linked polyethylene (XLPE) conductor shield.
    • Thermoset ethylene-propylene rubber (EPR) insulation.
    • SC XLPE insulation shield.
    • Copper tape 5 mil thick 25% minimum overlap metallic shield.
    • Oil Resistant, black sunlight resistance and flame retardant polyvinyl chloride (PVC) jacket.

    Application - MV105 25kV Copper Tape Shield:

    The MV105 25kV Copper Tape Shield is typically used as a primary power and distribution circuits in industrial and commercial installations. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends. Power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry locations, installed in cable trays, raceways, ducts and open-air, aerially or directly buried as permitted by NEC.

      

    Temperature Rating - MV105 25kV Copper Tape Shield:

    105°C Normal Operating Temperature

        

    Voltage Rating - MV105 25kV Copper Tape Shield:

    25 kV 100% and 133% IL

    ROHS stand compliant

     

    All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.