Type STO Cable
Type STO Cable
Sycor Part No | AWG | # of Conductors | Stranding | Insulation Thickness (In) | Nom. O.D. (In) | Jacket Thickness (In) | Temp | Voltage Rating | Approx Weight LBS./MFT | Ampacity | |
---|---|---|---|---|---|---|---|---|---|---|---|
STO182 | 18 | 2 | 16/30 | 0.030 | 0.354 | 0.060 | -40ºC to 60ºC | 600 | 73 | 10 |
|
STO183 | 18 | 3 | 16/30 | 0.030 | 0.372 | 0.060 | -40ºC to 60ºC | 600 | 77 | 10 |
|
STO184 | 18 | 4 | 16/30 | 0.030 | 0.403 | 0.060 | -40ºC to 60ºC | 600 | 103 | 7 |
|
STO162 | 16 | 2 | 26/30 | 0.030 | 0.376 | 0.060 | -40ºC to 60ºC | 600 | 75 | 13 |
|
STO163 | 16 | 3 | 26/30 | 0.030 | 0.396 | 0.060 | -40ºC to 60ºC | 600 | 91 | 13 |
|
STO164 | 16 | 4 | 26/30 | 0.030 | 0.427 | 0.060 | -40ºC to 60ºC | 600 | 109 | 18 |
|
STO142 | 14 | 2 | 41/30 | 0.045 | 0.515 | 0.080 | -40ºC to 60ºC | 600 | 130 | 18 |
|
STO143 | 14 | 3 | 41/30 | 0.045 | 0.541 | 0.080 | -40ºC to 60ºC | 600 | 160 | 15 |
|
STO144 | 14 | 4 | 41/30 | 0.045 | 0.581 | 0.080 | -40ºC to 60ºC | 600 | 194 | 25 |
|
STO122 | 12 | 2 | 65/30 | 0.045 | 0.585 | 0.095 | -40ºC to 60ºC | 600 | 175 | 25 |
|
STO123 | 12 | 3 | 65/30 | 0.045 | 0.614 | 0.095 | -40ºC to 60ºC | 600 | 216 | 20 |
|
STO124 | 12 | 4 | 65/30 | 0.045 | 0.664 | 0.095 | -40ºC to 60ºC | 600 | 263 | 30 |
|
STO102 | 10 | 2 | 104/30 | 0.045 | 0.642 | 0.095 | -40ºC to 60ºC | 600 | 232 | 30 |
|
STO103 | 10 | 3 | 104/30 | 0.045 | 0.672 | 0.095 | -40ºC to 60ºC | 600 | 278 | 30 |
|
STO104 | 10 | 4 | 104/30 | 0.045 | 0.729 | 0.095 | -40ºC to 60ºC | 600 | 340 | 25 |
|
STO083 | 8 | 3 | 65/.016 | 0.060 | 0.840 | 0.110 | -40ºC to 60ºC | 600 | 420 | 40 |
|
STO084 | 8 | 4 | 65/.016 | 0.060 | 0.950 | 0.125 | -40ºC to 60ºC | 600 | 470 | 35 |
|
STO063 | 6 | 3 | 133/.014 | 0.060 | 0.990 | 0.125 | -40ºC to 60ºC | 600 | 600 | 55 |
|
STO064 | 6 | 4 | 133/.014 | 0.060 | 1.10 | 0.140 | -40ºC to 60ºC | 600 | 800 | 45 |
|
Description of Type STO Cable:
Sycor’s Type STO portable cables are highly flexible, very versatile for outdoor use, flame retardant as well as resistant to moisture, water, acidic chemicals and Alkali.
Construction of Type STO Cable:
Flexible stranded copper conductors with colour-coded thermoplastic insulation.
Cabled with a filler, separator, and overall oil-resistant thermoplastic jacket.
Sizes 16, 14, 12 & 10 AWG are MSHA listed. All sizes UL listed.
Insulation of Type STO Cable:
Polyvinyl Chloride
Approvals of Type STO Cable:
UL Standard 62
CSA Standard 22.2 No. 49
Federal Spec JC-580B
NEC Article 400
OSHA
Application of Type STO Cable:
Sycor’s Type STO and SJTO portable cables are strong solutions involving machinery subject to extra hard use and requiring premium quality cords that are resistant to oils, lubricants and grease such as machine tools, portable power equipment, portable appliances, mixers, washing machines and polishers.
Temperature Rating of Type STO Cable:
-40°C to +60°C
Voltage Rating of Type STO Cable:
Type STO – 600 V
Amps per NEC Art. 400
Cold Bend for of Type STO Cable:
Meets UL cold bend test at -35°C
Colour options for Type STO Cable:
Colour Chart | ||
Cond. # | Colour | Tracer |
1 | Black | - |
2 | White | - |
3 | Red | - |
4 | Green | - |
5 | Orange | - |
6 | Blue | - |
7 | White | Black |
Value-Added Services for Type STO Cable:
All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.