MV90 2.4kV (5kv ICEA) - Non Shielded, XLPE Insulated
MV90 2.4kV (5kv ICEA) - Non Shielded, XLPE Insulated
Sycor Part No | AWG | Stranding | Conductor NOM. O.D. | Temp | Voltage Rating | UL Style | 100% Insulation Thickness | 100% Approx Weight Copper | 100% Approx Weight Alum. | |
---|---|---|---|---|---|---|---|---|---|---|
MV902.4K100-8 | 8 | 7 | 0.13 | 90°C | 2.4 kV | 1072 | 110 | 94 | - |
|
MV902.4K100-6 | 6 | 7 | 0.17 | 90°C | 2.4 kV | 1072 | 110 | 131 | 74 |
|
MV902.4K100-4 | 4 | 7 | 0.21 | 90°C | 2.4 kV | 1072 | 110 | 187 | 97 |
|
MV902.4K100-2 | 2 | 7 | 0.27 | 90°C | 2.4 kV | 1072 | 110 | 273 | 131 |
|
MV902.4K100-1 | 1 | 19 | 0.30 | 90°C | 2.4 kV | 1072 | 110 | 331 | 151 |
|
MV902.4K100-1/0 | 1/0 | 19 | 0.34 | 90°C | 2.4 kV | 1072 | 110 | 405 | 178 |
|
MV902.4K100-2/0 | 2/0 | 19 | 0.38 | 90°C | 2.4 kV | 1072 | 110 | 498 | 212 |
|
MV902.4K100-3/0 | 3/0 | 19 | 0.42 | 90°C | 2.4 kV | 1072 | 110 | 614 | 254 |
|
MV902.4K100-4/0 | 4/0 | 19 | 0.48 | 90°C | 2.4 kV | 1072 | 110 | 760 | 305 |
|
MV902.4K100-250 | 250 MCM | 37 | 0.52 | 90°C | 2.4 kV | 1072 | 120 | 898 | 361 |
|
MV902.4K100-350 | 350 MCM | 37 | 0.62 | 90°C | 2.4 kV | 1072 | 120 | 1227 | 474 |
|
MV902.4K100-500 | 500 MCM | 37 | 0.74 | 90°C | 2.4 kV | 1072 | 120 | 1715 | 641 |
|
MV902.4K100-750 | 750 MCM | 61 | 0.91 | 90°C | 2.4 kV | 1072 | 130 | 2539 | 928 |
|
MV902.4K100-1000 | 1000 MCM | 61 | 1.06 | 90°C | 2.4 kV | 1072 | 130 | 3344 | 1197 |
|
*Available in 100% and 133% Insulation Levels.
Description - MV90 2.4kV Non-Shielded:
The MV90 2.4kv is a designated medium voltage power cable.
Temperature Rating - MV90 2.4kV Non-Shielded:
90°C – Normal Operating Temperature
Voltage Rating - MV90 2.4kV Non-Shielded:
2.4 kV per UL
5 kV 100% and 3 kV133% per ICEA
Application - MV90 2.4kV Non-Shielded:
The MV90 2.4kv is typically used for primary power and distribution circuits in industrial and commercial installations, for use in wet or dry locations.
Per NEC, use is limited to 2400 volts.
Approvals - MV90 2.4kV Non-Shielded:
UL listed as MV-90 Wet and Dry
UL1072
ICEA S-96-659/NEMA WC71:
Non-shielded cables 2001 to 5000 volts for
electrical energy distribution
Construction - MV90 2.4kV Non-Shielded:
- Stranded, soft annealed bare copper conductor
- (Aluminum conductor available upon request)
- Semi-conducting cross-linked polyethylene (XLPE) conductor shield
- Black sunlight and track resistant thermoset cross-linked Polyethylene (XLPE) insulation
All specifications are provided for reference only. Specifications will vary between manufacturers and are subject to change without notice. Be sure to check with your sales rep for the most accurate and up to date information when ordering.