    Sycor Part No AWG# of ConductorsStrandingInsulation Thickness (In)Nom. O.D. (In)Jacket Thickness (In)Approx Weight LBS./MFT
    IMSA191021401B 142Solid0.0250.3290.04570
    IMSA191031401B 143Solid0.0250.3450.04587
    IMSA191041401B 144Solid0.0250.3760.04594
    IMSA191051401B 145Solid0.0250.4100.045129
    IMSA191061401B 146Solid0.0250.4460.045157
    IMSA191071401B 147Solid0.0250.4460.045170
    IMSA191081401B 148Solid0.0250.4830.045191
    IMSA191091401B 149Solid0.0250.5210.045211
    IMSA191101401B 1410Solid0.0250.5900.060250
    IMSA191121401B 1412Solid0.0250.6100.060287
    IMSA191021201B 122Solid0.0300.3830.04590
    IMSA191031201B 123Solid0.0300.4040.045124
    IMSA191041201B 124Solid0.0300.4450.045166
    IMSA191051201B 125Solid0.0300.4860.045189
    IMSA191061201B 126Solid0.0300.5550.060243
    IMSA191071201B 127Solid0.0300.5550.060276
    IMSA191081201B 128Solid0.0300.6000.060298
    IMSA191091201B 129Solid0.0300.6430.060326
    IMSA191101201B 1210Solid0.0300.7000.060350
    IMSA191111201B 1211Solid0.0300.7050.060390
    IMSA191121201B 1212Solid0.0300.7230.060415

    21 Items

    Set Descending Direction

    Additional strandings and gauges available upon request.
    Other IMSA Cable Specifications available upon request.

    Download Spec Sheet  

    Municpal Signal & Control Cable (IMSA 19-1)

    Description - Municipal Signal & Control Cable, IMSA:

    Solid bare copper conductors, colour coded polyethylene insulated conductors twisted with non-hygroscopic filers and Polyvinyl Chloride outer jacket.

     

    Approvals - Municipal Signal & Control Cable, IMSA:

    IMSA-Specification 19-1

     

    Construction - Municpal Signal & Control Cable, IMSA:

    Conforms to IMSA Specifications 19-1.
    Black Polyvinyl Chloride per ASTM D-1047 jacket.
    Polyethylene insulation.

    Temperature Rating - Municipal Signal & Control Cable, IMSA:

    -20°C to 75°C

     

    Voltage Rating - Municipal Signal & Control Cable, IMSA:

    600 Volts

     

    Application - Municipal Signal & Control Cable, IMSA:

    For use in signal and traffic systems in underground conduit, as aerial cable supported by a messenger, or installed in buildings.

    Colour options for Municipal Signal & Control Cable, IMSA:

    Black Colour 0